HomeMy WebLinkAboutItem #1 Fox Hollow Estates/ao'�C\
CHUBBUCK
1 0 0 H 0
Public Works Department
Development Services Division
290 E. Linden Avenue, Chubbuck, ID 83202
208.237.2430
www.CityofChubbuck.us
FOX HOLLOW ESTATES SUBDIVISION
PRELIMINARY PLAT REQUEST - STAFF REPORT
CITY OF CHUBBUCK LAND USE AND DEVELOPMENT COMMISSION
REGULAR MEETING ON JUNE 9, 2026
STAFF FINDINGS SUMMARIZED
After reviewing the proposed Fox Hollow Estates Subdivision preliminary plat, Staff finds that it appears
to meet the code requirements with the following comments:
Secondary irrigation facilities will be required to be designed and constructed in accordance
with section 16.12.230 of city code, which may require upgrades to the existing pump station
or the installation of an independent irrigation pump station.
Preliminary Plat recommendations are conditional upon City Council approval of Fox Hollow
Estates Subdivision.
Staff and Mayor Burch have reviewed the proposed access for phase 2 lots onto Philbin Road
and support the deviation from BTPO Access Management Guidelines as shown on the
preliminary plat.
STAFF RECOMMENDATION: Staff recommends approval of the preliminary plat with the following
conditions:
The final plat along with supporting documents be submitted in accordance with Title 17 of the
Chubbuck Municipal Code.
A secondary pressurized irrigation system be designed and constructed, which may require upgrades
to the existing irrigation pump station or the installation of an independent irrigation pump station.
FACTS
REQUEST: The applicant proposes a 12 lot Preliminary Plat for 12 residential building lots in the Fox Hollow
Estates Subdivision. It includes constructing Avery Street for access and extending water, sewer, and
irrigation mainlines with services to all lots.
BACKGROUND: This is the 15Y division of the Fox Hollow Estates Subdivision.
TYPE OF COMMISSION ACTION: Quasi -Judicial (Subject to appeal; decisions must be supported by
the evidence and by applying law to the facts; decisions shall be based on the standards for
approval). Recommendation/approval of this preliminary plat shall be whether it meets the requirements
of the City of Chubbuck ordinance and State of Idaho statutes. The Commission may recommend
approval with or without conditions, may table a decision, or may recommend denial of the
application.
OWNER:
Investments of Idaho LLC
2860 N. Rapid Creek Rd.
Inkom, ID 83245
PROFESSIONAL SERVICES:
Avyant / MBQ Engineering
161 Jefferson Ave.
Pocatello, ID 83201
LOCATION: NE 1/4 of Section 8, Township 6 South, Range 34 East, of the Boise Meridian, on the west
side of Philbin Road south of Deckyr Dr.. Generally located at SW corner of Philbin Rd. / Deckyr Dr.
intersection
SITE CHARACTERISTICS & ZONING:
CURRENT ZONING: Limited Residential (R-2)
CURRENT LAND USE: Residential
PROJECT SIZE: ±3.0 acres
VIEWS: Generally visible from the north and east
TOPOGRAPHY: Generally flat
EXISTING STRUCTURES: Yes
SURROUNDING LAND USES AND ZONING
NORTH: Residential; Limited Residential (R-2) zone
EAST: Civic, Agriculture; Limited Commercial (C-1) zone
SOUTH: Residential, vacant; Single Family Residential (R-1) zone
WEST: Residential; Limited Residential (R-2) zone
SERVICES:
RECENT TRAFFIC COUNTS:
2025: Philbin Rd at W. Chubbuck Rd, 7678/day
2025: Philbin Rd at Alpine Ave, 6440/day
ACCESS STREET: Current access from Deckyr Dr. for phase 1, Philbin Rd. for phase 2
FIRE/EMS PROTECTION: City of Chubbuck Fire Department
SANITARY SEWER: City of Chubbuck Sewer Utility Department
CULINARY WATER: City of Chubbuck Water Utility Department
SURFACE WATER RIGHTS: Fort Hall Irrigation Project
PROCEDURES:
In accordance with City Code 17.12.030-050 and Resolution 2025-06, a complete petition and
fees for a preliminary plat were filed with the City and which contained the appropriate
documents and waiver requests pursuant to 17.12.040.
In accordance with City Code 17.12.100, the application is scheduled to be heard at the June 9,
2026 Regular Meeting of the Land Use and Development Commission.
In accordance with City Code 17.12.080, notice were provided as follows:
a. Notices posted on the subject property.
b. Notices provided to City departments, other government agencies, and affected public
utility providers.
APPLICABLE LAWS AND PLANS:
1. Idaho Code
/94�0t\
CHUBBUCK
1AAAA
290 E. Linden Avenue, Chubbuck, ID 83202
208.237.2430
www.CityofChubbuck.us
a. §50-13, Plats and Vacations
b. §67-6513, Subdivision Ordinance
Chubbuck Comprehensive Plan (as amended)
Chubbuck City Code
a. Title 16, Land Improvement Standards
b. Title 17, Land Development
c. Title 18, Land Use
PUBLIC COMMENTS:
1. No written comments were received as of this report.
/944'C-\
CHUBBUCK
1AAAA
290 E. Linden Avenue, Chubbuck, ID 83202
208.237.2430
www.CityofChubbuck.us
STANDARDS FOR REVIEWING A PRELIMINARY PLAT
1. Does the Preliminary Plat comply with applicable laws and ordinances?
CITY CODE TITLE 17- LAND DEVELOPMENT
Compliant
Standards and Staff Comments
Yes
No
N/A
City Code
City Standard and Staff Comments
x
17.12.030,
Copies to be Submitted, Notice and Fee
17.12.050
Staff
The applicant has completed the requirements of these
Comments
sections.
Department
Public Works:
x
Comments
The department has reviewed the applicant's proposal for
compliance and finds that it meets the code requirements.
Concerns have been addressed by the applicant.
x
Department
Fire Department:
Comments
The department has reviewed the applicant's proposal for
compliance and finds that it meets the code requirements.
No comments received.
x
Department
Police Department:
Comments
The department has reviewed the applicant's proposal for
compliance and finds that it meets the code requirements.
No comments received.
CITY CODE TITLE 17 — PRELIMINARY PLAT STANDARDS
Compliant
Standards and Staff Comments
Yes
No
N/A
City Code
City Standard and Staff Comments
x
17.12.150
Form of Presentation
Staff
Applicant has provided all information required of this section.
Comments
x
17.12.160
Identification and Descriptive Data
Staff
Applicant has provided all information required of this section.
Comments
x
17.12.170
Existing Conditions Data
Staff
Applicant has provided a preliminary plat showing existing
Comments
contours, locations of existing water and sewer systems, street
names and rights-of-way, and all other information required of
this section.
x
17.12.180
Proposed Conditions Data
Staff
Applicant has provided a preliminary plat showing proposed
Comments
conditions including lot dimensions, easement use and
locations, and street layout including proposed dedication of
additional right-of-way.
x
17.12.190
Proposed Utility Methods
Staff
Water, sewer, and irrigation will be extended into the
Comments
development, applicant has provided service locations shown
on the preliminary plat.
1940't-\
CHUBBUCK
1 0 A H 0
290 E. Linden Avenue, Chubbuck, ID 83202
208.237.2430
www.CityofChubbuck.us
CITY CODE TITLE 78- LAND USE
Compliant I Standards and Staff Comments
Yes I No I N/A I City Code I City Standard and Staff Comments
Agency
BTPO
Bureau of Indian Affairs
Sparklight
Century Link
Direct Communications
ID Fish and Game
ID Transportation
Idaho Power
Intermountain Gas
School District 25
SE Idaho Public Health
US Postal Service
/94�4c\
CHUBBUCK
1AAAA
OTHER AGENCY COMMENTS AND REQUIREMENTS
No comment received.
No comment received.
No comment received.
No comment received.
No comment received.
No comment received.
No comment received.
No comment received.
No comment received.
No comment received.
No comment received.
No comment received.
Comment
290 E. Linden Avenue, Chubbuck, ID 83202
208.237.2430
www.CityofChubbuck.us
18.08.042A
Height and area Regulations
x
Staff
This is proposed in the (R-2) zone and is limited to 35 ft high
Comments
and 6000 minimum lot size.
18.08.044
Lot Width to depth ratio
x
Staff
This is proposed in the (R-2) zone, maximum ratio is 1:2
Comments
PUBLIC IMPROVEMENT REQUIREMENTS
Improvement
Description
Water mainlines with services will be constructed and connected to existing
Water
water mainlines.
Sewer mainlines with services will be constructed and connected to existing
Sewer
sewer mainlines.
Right-of-way will be dedicated and the street will be constructed per 16.12.020C
Streets
and in accordance with the comprehensive plan.
Storm water from the street will be retained in the roadway drainage swale, while
Storm Drainage
storm water from the lots will be required to be retained on site.
Pressurized Secondary
Secondary irrigation facilities will be designed and constructed in accordance
Irrigation
with section 16.12.230 of city code.
Parks
Park impact fees will be required for this development.
Agency
BTPO
Bureau of Indian Affairs
Sparklight
Century Link
Direct Communications
ID Fish and Game
ID Transportation
Idaho Power
Intermountain Gas
School District 25
SE Idaho Public Health
US Postal Service
/94�4c\
CHUBBUCK
1AAAA
OTHER AGENCY COMMENTS AND REQUIREMENTS
No comment received.
No comment received.
No comment received.
No comment received.
No comment received.
No comment received.
No comment received.
No comment received.
No comment received.
No comment received.
No comment received.
No comment received.
Comment
290 E. Linden Avenue, Chubbuck, ID 83202
208.237.2430
www.CityofChubbuck.us
EXAMPLE MOTIONS
APPROVAL:
Having reviewed the petition materials, staff report, and all testimony presented before and by the City
in this hearing as part of the record against criteria established by City Code 17.12.100, and having
found that those criteria for approving a preliminary plat request are satisfied, I move to recommend
approval of the preliminary plat as described in the application materials to the City Council with the
following conditions and waiver recommendations:
1. (if found necessary by LUDC).
APPROVAL (NO CONDITIONS):
Having reviewed the petition materials, staff report, and all testimony presented before and by the City
in this hearing as part of the record against criteria established by City Code 17.12.100, and having
found that those criteria for approving a preliminary plat request are satisfied, I move to recommend
approval of the preliminary plat as described in the application materials.
DENIAL:
Having reviewed the petition materials, staff report, and all testimony presented before and by the City
in this hearing as part of the record against criteria established by City Code 17.12.100, and having
found that those criteria for approving a preliminary plat request are not satisfied, I move to
recommend denial of the preliminary plat request as described in the application materials.
I find that the petition fails to comply with... [CITE SPECIFIC STANDARD WHICH IS NOT MET AND
DESCRIBE WHY IT WAS NOT MET].
SPECIAL CONSIDERATIONS FROM IDAHO CODE:
• I.C. 67-6513: Denial of a subdivision permit or approval of a subdivision permit with conditions
unacceptable to the landowner may be subject to the regulatory taking analysis provided for
by section 67-8003, Idaho Code, consistent with the requirements established thereby.
REPORT: Sean Harris, Development Services Manager Staff comments in this report are based solely
sharris@cityofchubbuck.us upon evidence available at the time of the
(208) 237-2430 report. Additional information may be
brought to light at or before the hearing.
DATE: May 19, 2026
EXHIBITS
1. Reference Map
2. Application for Preliminary Plat
3. Plat
4. Narrative for Preliminary Plat
5. Maps
a. Future Land Use
/94�4c\
CHUBBUCK
1AAAA
290 E. Linden Avenue, Chubbuck, ID 83202
208.237.2430
www.CityofChubbuck.us
b. Current Zoning
6. Evidence of Notice
a. Site Postings
b. Agency notices on file w/staff
/944,C-\
CHUBBUCK
1AAAA
290 E. Linden Avenue, Chubbuck, ID 83202
208.237.2430
www.CityofChubbuck.us
Exhibit 1:
Reference Map - Fox Hollow Estates Subdivision
CHUBBUCK
290 E. Linden Avenue, Chubbuck, ID 83202
208.237.2430
www.CityofChubbuck.us
CHUBBUCK
I D R H D
290 E. Linden Avenue Chubbuck, ID 83202
208.237.2430
www.CityofChubbuck.us
PRELIMINARY PLAT
APPLICATION
Dec. 2024 Form- Replaces Prior Versions
PAGE 1 OF 5
Requirements and procedures for Preliminary Plat applications are found in section 17.12.030 — 1712.190 of municipal code. The following
must be completed and submitted with all required documents in order to progress to the next stage of the review process; failure to submit a
complete application packet may result in additional fees.
DATE RECEIVED: INITIALS: FEES PAID? Y N AMOUNT:
SECTION A —DEVELOPER/APPLICANT INFORMATION
Al.
Name
A2.
Mailing Address
City
State Zip Code
A3.
Phone Number (including area
code)
A4. Email Address
SECTION B — PROFESSIONAL SERVICES INFORMATION
B1.
Firm Name
B2.
Mailing Address
City
State
Zip Code
B3.
Point of Contact (Name)
B4. Email Address
SECTION C — SITE INFORMATION
Cl.
Site Address
City Zip
C2. Tax Parcel #(s)
C3.
Current Land Use
C4. Are there existing structures on-site?
❑ Yes ❑ No
C5.
Is the site under contractor in the name of the developer/applicant?
❑ Yes ❑ No
C6. Approximate size of property
C7.
Are there any existing items of which Staff should be aware?
❑ Yes ❑ No If yes:
C8. Does the site contain irrigation water rights?
❑ Yes ❑ No
If yes, which company/district:
CHUBBUCK
I D R H III
290 E. Linden Avenue Chubbuck, ID 83202
208.237.2430
www.CityofChubbuck.us
PRELIMINARY PLAT
APPLICATION
Dec. 2024 Form- Replaces Prior Versions
PAGE 2 OF 5
SECTION D — PROPOSED DEVELOPMENT INFORMATION
D1. Plat Name
D2. Number of Lots
D3. Type of Land Uses within development (residential, commercial, industrial, etc.)
D4. Water & Sewer Needs
D5. Are there any issues related to the development of which Staff should be aware prior to meeting?
❑ Yes ❑ No If yes:
Will the development contain any commonly -owned and/or maintained improvements (stormwater facilities, community mailboxes, streets,
D6. parks/playgrounds, etc.)?
❑ Yes ❑ No If yes, what?
Will the development contain any land within a designated floodplain (FEMA or Chubbuck?
❑ Yes ❑ No If yes, what zone?:
D7.
If yes, how do you intend to minimize flood damage to structures, and public utilities and facilities such as sewer, gas, water, and electrical systems??
If yes and the proposal contains more than 50 lots or more than 5 acres, whichever is lesser, and there no base flood elevations
established for the floodplain, you must submit base flood elevation data with the application package.
Only for plat containing residential units: The City has adopted Parks Impact Fees with requirements that parks impact fees are due when building permits
for residential units are issued. There may be times when the developer proposes to dedicate land and/or construct park improvements to satisfy the parks
impact fee funding obligation in whole or in part. Which is anticipated with this development?
D6. ❑ No public parks/park land are proposed with this phase, or any public parks/park land will benefit only this development, parks
impact fees will be collected
❑ Public parks/park land are proposed that will benefit more than just this development, parks impact fees may be adjusted only by
agreement between the city and the developer prior to construction, fund, or contribution based on the present value of system
improvements and land in accordance with Chapter 17.28 of municipal code.
SECTION E — ADDITIONAL SUBMITTAL REQUIREMENTS
E1. Preliminary Plat Application Fees: Total # of lots X $20.00 + $550.00 base fee = $ total
Public Notice Sign Deposit (full or partial refund at Director's discretion) = $ 100.00
❑ Traffic Impact Analysis Report Review fee (if required) = $ 500.00
$ total due
E2. Master Plan, for any preliminary plat that is a portion of a large parcel, part of a larger group of commonly held parcels, or
part of a larger development which has been, or shall be developed by the developer, shall be accompanied by a master plan
submitted during the preliminary platting process. A master plan must be submitted with each preliminary plat filed.
E3. Preliminary codes, covenants, and restrictions (CC&Rs) addressing maintenance of commonly owned improvements and/or
land, if the development will contain any commonly owned improvements and/or land. For purposes of this requirement,
commonly owned improvements include stormwater facilities, cluster mailboxes, private open space/parks/amenities, etc.
E4. Narrative indicating how the approval criteria for preliminary plats are addressed. Approval criteria are as follows (17.12.100):
1. The subdivision proposal complies with applicable provisions of this title.
2. The subdivision proposal complies in principle with all applicable city design standards and development regulations.
CHUBBUCK
I D R H D
290 E. Linden Avenue Chubbuck, ID 83202
208.237.2430
www.CityofChubbuck.us
PRELIMINARY PLAT
APPLICATION
Dec. 2024 Form- Replaces Prior Versions
PAGE 3 OF 5
3. The subdivision proposal complies with all applicable zoning requirements of the underlying zoning district, applicable
overlays, and other applicable development standards.
4. All public facilities including streets, sidewalks, curbs, gutters, secondary pressurized irrigation, water, sewer, fire
protection, and sanitation services can be provided to the newly created lots and accommodate future extension to
adjacent land. The use of a "control strip" intended to control or prevent the future extension of public facilities or
development of adjacent land is prohibited.
5. If city public works determines that the proposed subdivision will result in significant traffic impacts then a "traffic impact
study" will be required as part of the commission's review. A significant traffic impact is generally defined as occurring
when:
a. A proposed development or redevelopment of a site will generate 100 or more new peak hour trips; or
b. The added volume is equal to 1,000 vehicles per day.
6. The proposal provides for a continuation of a connected transportation system unless topography or natural features
prevents a connection to abutting streets or property.
7. The proposed subdivision provides for bicycle and pedestrian transportation routes and amenities in accordance with
Bannock Transportation Planning Organization's adopted bicycle and pedestrian plans.
8. Public utilities are provided to the newly created lots in public rights of way or in appropriately sized easements.
E5. If the development contains area with any FEMA or City of Chubbuck designated floodplains, the following must be
submitted:
1. If the development, either within a single phase or as part of a larger planned development, contains more than 50 lots or
5 acres, whichever is less, base flood elevations shall be determined prior to filing an application for a preliminary plat
and said determinations must be submitted with the application package.
2. If the development, either within a single phase or as part of a larger planned development, contains more than 50 lots or
5 acres, whichever is less, evidence must be submitted demonstrating that a CLOW application has been filed with
FEMA.
E6. Traffic Impact Analysis — Category A, Category B, or Statement. Follow the Traffic Impact Analysis Guidelines as adopted from
Bannock Transportation Planning Organization.
E7. If the application is presented by someone other than the property owner of record, an Affidavit of Legal Interest is required,
signed by property owner(s) and notarized.
a. If a Trust is the owner, include a copy of the Trust and any later document modifying the Trust to indicate the Trustee
authorized to sign and make application.
b. If an LLC or other entity is the owner, provide proof that the person signing the application on behalf of the entity is the
Authorized Agent to do so.
E8. Because every application is different, rules and regulations may differ and staff may require additional information or
submittals before an application can be deemed complete and ready for the review process beyond staff level.
CHUBBUCK
I D R H D
290 E. Linden Avenue Chubbuck, ID 83202
208.237.2430
www.CityofChubbuck.us
PRELIMINARY PLAT
APPLICATION
Dec. 2024 Form- Replaces Prior Versions
PAGE 4 OF 5
E9. PDF Drawings drawn according to municipal code containing the following:
Code Reference
Staff
Reviewers
Initials
Preparer's Description
Initials
17.12.150 —17.12.160
Presentation & Descriptive Data
• Drawing Size (11"x22" minimum through 22"x34" maximum)
• Proposed Name
• Location of Development by Section, Township, Range
• Reference to Section or Quarter Corner (dist. & Bear.)
• Name, Address, Phone Number of Developer
• Name, Address, Phone Number of Engineer/Surveyor
• North Arrow
• Date of Preparation (Including Revisions)
• Vicinity Map
17.12.170
Existing Conditions
• Existing Contours @ adequate Interval
• Existing Features
• Existing Utilities
• Existing R -O -W, easements, public areas, corporation lines
• Instrument # for parcels with common boundaries
• Existing & proposed zoning
• Total acreage
• Boundary dimensions
17.12.180
Proposed Conditions
• Street layout (including width)
• Street names
• Connections to existing streets
• Lot dimensions
• Lot numbers
• Total number of lots
• Location, width, and use of easements
• Designation of land for public use (parks and open space)
17.12.190
Proposed Utility Methods
• Proposed sewage disposal
• Proposed water supply
• Proposed storm water disposal
• Proposed secondary pressurized irrigation (if the site has irrigation
rights)
15.54 (adopted 6/3/20)
Floodplain requirements (N/A if there is no floodplain in the development)
• Floodplain boundaries, type, and BFEs
290 E. Linden Avenue Chubbuck, ID 83202 PRELIMINARY PLAT
lao�c\_ 208.237.2430
CHUBBUCK www.CityofChubbuck.us APPLICATION
Dec. 2024 Form- Replaces Prior Versions
IOAHa PAGE 5OF5
SECTION F—CERTIFICATION
• 1, the undersigned, hereby certify that the information herein and attached hereto is true and correct to the
best of my knowledge.
• 1 agree to comply with all provisions of ordinances and laws governing this type of work, whether specified
herein or not.
+ 1 am aware that if this application is not complete, the preliminary plat review process will not continue until
it is so deemed by the City upon further submission of materials.
• 1 hereby authorize the filing of this application and grant approval of on-site review of the development
described herein.
• 1 certify that I am authorized to file this application.
F1. Signature F2. Printed Name F3. Date
Jay Roche 1122126
SECTION G—FOR STAFF USE ONLY
G1. COMPLETENESS REVIEW:
Deemed complete?
Reviewed by: Date:
❑ Yes ❑ No If no, Iist concern(s):
Applicant Notified?
❑ Yes ❑ No Comments:
_ _ss-) -ss-) -ss-) -ss-) -ss-) -ss-) -ss-)
DECKYR DRIVE
w "_W W W W A
NICHOLAS FR/DEN
INST. NO. 22124851
NICHOLAS FR/DEN I
INST. NO. 22124851
C-
=3
1
15.0'
P.U.E
LOT 1 i
9,380 S.F.
0.21 AC. �_
IM
I M -
0
z �
mMI- -
SS
sS ) -ss-) -ss-)
=30' S 89043'09" W 407.05'
T� \�
0 0 o c
- f X9:33' V
NORTHEAST CORNER OF SECTION 8t89
S FOUND ALUMINUM CAP
MONUMENT PLS 19405 IN VAULT
PER CP&F#22213751
O
rn
\ m
A
N
0
tri
Z
92.0167.03
RETAIN AND PROTECT THE EXISTING WELL
UNTIL THE EXISTING HOME IS CONNECTED \
INTO THE CITY'S WATER SYSTEM AS PART
OF THE PHASE 2 IMPROVEMENTS - - - - a
NO ADDITIONAL OR WIDENED ACCESS TO
W 15.0' I PHILBIN ROAD FROM THE EXISTING HOUSE
W P.U.E. vv LOT WILL BE ALLOWED BEYOND WHAT IS I
11= EXISTING SHOWN. SHOULD THE LOT REDEVELOP IN
11-- LOT 7 SHED THE FUTURE, A NEW ACCESS WILL BE I
9,280 S.F. M REQUIRED TO COME OFF OF DECKYR DRIVE
0 0.21 AC. - - -
00
Lu
I
Q i M I LOT 8-
z M 15,741 S.F.
- - -
1% 0.36 AC.
N 89043'09'
I I
I U I o 4,,802 ASCF
110.N89°2. .
0'2 " E 19
4987.S.F. °p
°
°
°
0.11 AC.
120.0' BLOCK 1
S 89-20-24" W 138.00'
29.00' 80.00' 29.00' I 20.0'
m q I I N 89020'24" E 109.04'
REMOVE ANY EXISTING FENCES WITHIN THE PROJECT LIMITS
ss % ss ss THAT INTERFERE WITH THE PROPOSED PHASE 1IMPROVEMENTS
011
011 F_
C
d0 M O
v
-It4798
SF
CDo
GENE L. WARREN LOT 3 � LOT 4 3:LOT 5
INST NO. 2161644110.515 S.F. 8,067 S.F. 10,607 S.F.
0.24 AC. fn 0.18 AC. 0.24 AC.
CD
BLOCK 1 rn 0
z z
IR F_
N
R R - 84.00' 1 80.00' 1 84.01'
N 89043'16" E 407.05
DEVELOPER TO COORDINATE UPGRADES AND
LEROY HOUSE CONNECTION INTO THE EXISTING IRRIGATION SYSTEM ISGAR RAMOS MATTISON B. HARDING
INST NO. 21711286 TO SUPPORT THE ADDITIONAL PROPOSED CONNECTIONS INST. NO. 22208551 INST. NO. 21807232
1 15.0' 1 55.0'
4.0' 9.0' SWALE 18.5' 18.5'
W
z STANDARD CITY ROAD SECTION (37' TBC TO TBC)
z I 2.5" -ASPHALT PAVEMENT
uj
3" - 3/4" MINUS AGGREGATE
8" - 2" MINUS BASE
CUT "a FLAT 2.0%
2.0% SLOPE W/ SEPARATION FABRIC UNDERNEATH 2.0% SLOPE
4" THICK CONCRETE SIDEWALK 12" RIBBON CURB TYPICAL STREET SECTION (AVERY STREET)
(NOT TO SCALE)
0.11 AC.
N 89020'24" E 109.04'
4,866 S.F.
0.11 AC.
9.0' SWALE
12" RIBBON CURB
109.04'
TAMARA AYN RIRIE
INST. NO. 22119930
4.0'
O
00
I N
I
15.0'
i P.U.E.
I 1b
C)
6 O
19
co w
N
M
0
Ln
0
O
16.0'
ACCESS
o I EASEMENT
0
O
4
15.0'
FLAT
4" THICK CONCRETE SIDEWALK
cc
SECTION LINE
L1
S 89020'24" W
96.50'
L2
X
PROPOSED PROPERTY LINE
"'
M
dl
-
1 S 89020'24" W 96.50'
PROPOSED EASEMENT LINE
M
C2
EXISTING PROPERTY LINE
SEEM
o
EXISTING CENTER LINE
- - - -
26.87'
LMM
X X X -
d
O
EXISTING FENCE LINE
�s
5.
SEWER LINE
3636 JASON AVENUE
O
EXISTING / PROPOSED SEWER MANHOLE
w_ /
w_
EXISTING WATER LINE
208-681-9228
® B
EXISTING / PROPOSED FIRE HYDRANT, WATER VALVE
quayleengl989@gmail.com
I
�
M
_
o
W
P
ti
PROPOSED SEWER LINE
x
m
t
¢Z
0
a
W
=
x
PROPOSED SEWER SERVICE LINE
�I
ss ss
EXISTING / PROPOSED SEWER SERVICE
0
0
PROPOSED WATER LINE
O
PROPOSED WATER SERVICE LINE
PROPOSED STORM LINE
ss
I ^
PROPOSED CATCH BASIN
ss
PROPOSED IRRIGATION LINE
(9
PROPOSED IRRIGATION BOX
PROPOSED CURB & GUTTER
W
PROPOSED SIDEWALK
p
Ln
I
PHASE 1
OLn
1-0RETAIN
PHASE 2
1°
m
AND PROTECT THE EXISTING SEPTIC SYSTEM UNTIL THE EXISTING HOME IS
N
m
CONNECTED INTO THE CITY'S SEWER SYSTEM AS PART OF THE PHASE 2 IMPROVEMENTS
NATHAN R. PALMER
LOT Z
I
W
M
I LOT 6 0
0
INST. NO. 21616818
z
0
8,028 S.F.
0
0
8,028 S.F.
m�
0.18 AC.
I z
z
00
I 0.18 AC.00
IR
C
I
I
I
m
r
m
m
REMOVE EXISTING BARN
z
I
I
I
�W
I �
M
M
r
- --
toI
I
S 89020'24" W 77.50'
S 89020'24" W 77.50'
R= 28
R=28'
55.00'
22.50'
22.50'
55.00'
,<
NATHAN R. PALMER
INST. NO. 21616818
_
o
-
-
- - - - -
- - - - - - -
- - - L -
-
X k
X X
_
IR
o
'
CD
o
-
-
00
N 89020'24" E 120.00'
c
7
N 89043'09'
I I
I U I o 4,,802 ASCF
110.N89°2. .
0'2 " E 19
4987.S.F. °p
°
°
°
0.11 AC.
120.0' BLOCK 1
S 89-20-24" W 138.00'
29.00' 80.00' 29.00' I 20.0'
m q I I N 89020'24" E 109.04'
REMOVE ANY EXISTING FENCES WITHIN THE PROJECT LIMITS
ss % ss ss THAT INTERFERE WITH THE PROPOSED PHASE 1IMPROVEMENTS
011
011 F_
C
d0 M O
v
-It4798
SF
CDo
GENE L. WARREN LOT 3 � LOT 4 3:LOT 5
INST NO. 2161644110.515 S.F. 8,067 S.F. 10,607 S.F.
0.24 AC. fn 0.18 AC. 0.24 AC.
CD
BLOCK 1 rn 0
z z
IR F_
N
R R - 84.00' 1 80.00' 1 84.01'
N 89043'16" E 407.05
DEVELOPER TO COORDINATE UPGRADES AND
LEROY HOUSE CONNECTION INTO THE EXISTING IRRIGATION SYSTEM ISGAR RAMOS MATTISON B. HARDING
INST NO. 21711286 TO SUPPORT THE ADDITIONAL PROPOSED CONNECTIONS INST. NO. 22208551 INST. NO. 21807232
1 15.0' 1 55.0'
4.0' 9.0' SWALE 18.5' 18.5'
W
z STANDARD CITY ROAD SECTION (37' TBC TO TBC)
z I 2.5" -ASPHALT PAVEMENT
uj
3" - 3/4" MINUS AGGREGATE
8" - 2" MINUS BASE
CUT "a FLAT 2.0%
2.0% SLOPE W/ SEPARATION FABRIC UNDERNEATH 2.0% SLOPE
4" THICK CONCRETE SIDEWALK 12" RIBBON CURB TYPICAL STREET SECTION (AVERY STREET)
(NOT TO SCALE)
0.11 AC.
N 89020'24" E 109.04'
4,866 S.F.
0.11 AC.
9.0' SWALE
12" RIBBON CURB
109.04'
TAMARA AYN RIRIE
INST. NO. 22119930
4.0'
O
00
I N
I
15.0'
i P.U.E.
I 1b
C)
6 O
19
co w
N
M
0
Ln
0
O
16.0'
ACCESS
o I EASEMENT
0
O
4
15.0'
FLAT
4" THICK CONCRETE SIDEWALK
50.00'
W
z
w
W
Ln
w
LEGEND
cc
SECTION LINE
L1
-
Z
L2
X
PROPOSED PROPERTY LINE
EM/EMEM
W
M
dl
-
19.00'
PROPOSED EASEMENT LINE
M
C2
EXISTING PROPERTY LINE
SEEM
o
EXISTING CENTER LINE
- - - -
26.87'
EXISTING EDGE OF GRAVEL
X X X -
d
O
EXISTING FENCE LINE
�s
5.
SEWER LINE
3636 JASON AVENUE
O
EXISTING / PROPOSED SEWER MANHOLE
w_ /
w_
EXISTING WATER LINE
208-681-9228
® B
EXISTING / PROPOSED FIRE HYDRANT, WATER VALVE
quayleengl989@gmail.com
W N ®
EXISTING / PROPOSED WATER METER, WATER SERVICE
_
o
W
P
ti
PROPOSED SEWER LINE
x
m
t
¢Z
0
a
W
=
x
PROPOSED SEWER SERVICE LINE
�I
ss ss
EXISTING / PROPOSED SEWER SERVICE
PROPOSED WATER LINE
50.00'
W
z
w
W
Ln
w
LEGEND
0
VICINITY MAP TI SIPHON ROAD
m
a
INTERSTATE 86
LINE TABLE
unuu
1111111
■
:- .� �. ■■1t■■ -ME
- :- - 111111■-
::::: :�-.:::: C. ----■111111:I
■.■■■
00
....:
!--- ---��--i
.........
am
I- == = ' :::: -- �� 1111■■1� i
-:--ME -1111111.1
::..--■111111-;
:�■■111111111
••
� 1�: ■■■1. 1111111 :111
1 ■11\�: ■11111::: 11111:
�■""�1" "'':11 ■11111111
sm
111111111
,� ■■■1111 On::-
..•• •il■1111p t11111� ���� ::�
� .� .� Qlno 14�- .- ■_ice un :
:% � e .... ■::::= _'1111111
��:pCin pug=■=i■�U���;
111 ■t1��R11■■■■�
1111111 � � ■t■ ■I1. �� �
I������ : ■1111■II■■
.....■ . - ■11...11■
101
1.
Ilumr. .uuu■ u
111~111 � � ■■■■■� �■
1111111 - - •••••• ••
II1111� :.........
..........
..........
1111111 1d
. 11■■■■: -.151,1112-51101
NUMBER
DIRECTION
SECTION LINE
L1
-
PROPOSED BOUNDARY LINE
L2
S 44°20'24" W
PROPOSED PROPERTY LINE
L3
N 46039'02" W
-
19.00'
PROPOSED EASEMENT LINE
26.87'
C2
EXISTING PROPERTY LINE
S 45°39'36" E
19.00'
EXISTING CENTER LINE
- - - -
26.87'
EXISTING EDGE OF GRAVEL
X X X -
d
O
EXISTING FENCE LINE
_ss -',EXISTING
5.
SEWER LINE
3636 JASON AVENUE
O
EXISTING / PROPOSED SEWER MANHOLE
w_ /
w_
EXISTING WATER LINE
208-681-9228
® B
EXISTING / PROPOSED FIRE HYDRANT, WATER VALVE
quayleengl989@gmail.com
W N ®
EXISTING / PROPOSED WATER METER, WATER SERVICE
_
o
W
P
ti
PROPOSED SEWER LINE
SUBDIVISION
m
t
¢Z
0
a
W
=
v'f
w
x
CD
o
w
PROPOSED SEWER SERVICE LINE
ss ss
EXISTING / PROPOSED SEWER SERVICE
PROPOSED WATER LINE
O
PROPOSED WATER SERVICE LINE
PROPOSED STORM LINE
e
PROPOSED CATCH BASIN
PROPOSED IRRIGATION LINE
(9
PROPOSED IRRIGATION BOX
PROPOSED CURB & GUTTER
W
PROPOSED SIDEWALK
PHASE 1
PHASE 2
0
VICINITY MAP TI SIPHON ROAD
m
a
INTERSTATE 86
LINE TABLE
unuu
1111111
■
:- .� �. ■■1t■■ -ME
- :- - 111111■-
::::: :�-.:::: C. ----■111111:I
■.■■■
00
....:
!--- ---��--i
.........
am
I- == = ' :::: -- �� 1111■■1� i
-:--ME -1111111.1
::..--■111111-;
:�■■111111111
••
� 1�: ■■■1. 1111111 :111
1 ■11\�: ■11111::: 11111:
�■""�1" "'':11 ■11111111
sm
111111111
,� ■■■1111 On::-
..•• •il■1111p t11111� ���� ::�
� .� .� Qlno 14�- .- ■_ice un :
:% � e .... ■::::= _'1111111
��:pCin pug=■=i■�U���;
111 ■t1��R11■■■■�
1111111 � � ■t■ ■I1. �� �
I������ : ■1111■II■■
.....■ . - ■11...11■
101
1.
Ilumr. .uuu■ u
111~111 � � ■■■■■� �■
1111111 - - •••••• ••
II1111� :.........
..........
..........
1111111 1d
. 11■■■■: -.151,1112-51101
NUMBER
DIRECTION
DISTANCE
L1
S 45°39'36" E
23.92'
L2
S 44°20'24" W
24.29'
L3
N 46039'02" W
23.70'
.111111.
.111111.
CURVE TABLE
NUMBER
DELTA ANGLE
CHORD DIRECTION
TANGENT
RADIUS
ARC LENGTH
CHORD LENGTH
C1
90000'00"
N 44020'24" E
19.00'
19.00'
29.85'
26.87'
C2
90000'00"
S 45°39'36" E
19.00'
19.00'
29.85'
26.87'
NOTES
O'
DEVELOPER INFORMATION
1.
EXISTING ZONING: AGRICULTURAL (A)
INVESTMENTS OF IDAHO LLC
2.
PROPOSED ZONING: RESIDENTIAL (R-2)
2860 N. RAPID CREEK RD.
3.
LOT SIZE DATA:
INKOM, ID 83245
¢
REQUIRED MINIMUM: 7,000 S.F.
208-681-4440
z
z
PROPOSED MINIMUM: 8,028 S.F.
rocheelectricinc@gmail.com
4.
SUBDIVISION STATS:
J
Z
m
3.00± ACRES
ENGINEER OF RECORD
d
O
12 RESIDENTIAL LOTS
MBQ ENGINEERING LLC
5.
GAS, POWER, CABLE TV ETC. TO BE PROVIDED
3636 JASON AVENUE
6.
EASEMENTS ARE 15' (FT.) WIDE UNLESS OTHERWISE NOTED
POCATELLO, ID 83204
7.
PROJECT WILL BE COMPLETED IN 2 PHASES. PHASE 1 WILL BE
208-681-9228
z
COMPLETED NOW AND PHASE 2 WILL BE COMPLETED IN THE FUTURE.
quayleengl989@gmail.com
8.
LOTS 9 THRU 12 OF BLOCK 1 ARE FOR TWIN HOME DEVELOPMENT ONLY.
_
o
W
P
ti
FOX HOLLOW ESTATES
SUBDIVISION
PROJECT LOCATED IN THE NE 1/4 OF THE NE 1/4 OF SECTION 8, TOWNSHIP 6 SOUTH,
RANGE 34 EAST, BOISE MERIDIAN, BANNOCK COUNTY, IDAHO
AVYANT
H �
� z
J
w
rvq
HALF SIZE SCALE (1 2 "x18')
1 INCH = 40 FEET
0 20 40
0 20 40
1 INCH = 20 FEET
FULL SIZE SCALE (24"x36')
O'
z
a
a
z
¢
v
,..
v
N
i
�
Q
�n
N
o
a
Q
¢
J
W
O¢
z
z
x¢
W
¢
x
0
z
O_
x
J
Z
m
Z
Q
"Z'
o
d
O
owc
w
0
=
v
W0
o
CC
w
z
N
w
tz
m
z
tD
O
M
E3
U
_
o
W
P
ti
w
�
m
t
¢Z
0
a
W
=
v'f
w
x
CD
o
w
O
O
W
m
N
m
w
W
in
z
S:2
H �
� z
J
w
rvq
HALF SIZE SCALE (1 2 "x18')
1 INCH = 40 FEET
0 20 40
0 20 40
1 INCH = 20 FEET
FULL SIZE SCALE (24"x36')
z
o
z
a
a
z
¢
v
,..
v
N
i
W
Q
�n
N
cD
E
a
Q
¢
J
W
O¢
z
z
x¢
W
¢
x
o
Vl
z
O_
x
J
Z
m
Z
Q
"Z'
o
d
O
owc
w
0
=
O
¢
W0
o
=
0
z
z
tz
m
z
tD
Ld
m
w
M
E3
U
_
o
W
P
ti
Z
S:2
Ln
Lu
w
O
v,
m
t
¢Z
0
a
W
=
v'f
w
x
CD
o
w
z
CD
V7
i
m
Q
J
LLj
N
�
z
Lon
W
C)
1
Lu
DC
�
J
C)
C)
LJ_
�
S \ONA L
�G\STE
\O
F OF P'�
QvP
SHEET NUMBER
15.0'
7 cjj��"' FLAT I 2
4" THICK CONCRETE SIDEWALK
50.0'
5.0' 1 12.5' SWALE
6" VERTICAL CURB & GUTTER
TYPICAL STREET SECTION (PHILBIN ROAD
(NOT TO SCALE)
rL
32.5'
2.0% SLOPE
STANDARD CITY ROAD SECTION (70' TBC TO TBC)
4" -ASPHALT PAVEMENT
6" - 3/4" MINUS AGGREGATE
16" - 2" MINUS BASE
W/ SEPARATION FABRIC UNDERNEATH
FOX HOLLOW ESTATES SUBDIVISION
PROJECT LOCATED IN THE NE 1/4 OF THE NE 1/4 OF SECTION 8, TOWNSHIP 6 SOUTH,
RANGE 34 EAST, BOISE MERIDIAN, BANNOCK COUNTY, IDAHO
A V Y A N T
\ONAL FN
O� �G\STE,q
H Q
� z
Lu
a Q�FOF\JP��
IF
HALF SIZE SCALE (12"x18')
1 INCH = 40 FEET
0 20 40
0 20 40
1 INCH = 20 FEET
FULL SIZE SCALE (24"x36')
SHEET NUMBER
PP -2
z
V
O
J
z � }
z z
¢ v
v
cr
c
G
w
coo
Q
p
W
0
= W Q W
LPI� Q W ¢ ~—i
_ d
Z ¢ O O J
_ W
O U
WpCD
=
o
m
�
a
�
Q
o
m
W
W C =
W L% CD
Q
o
Z
W
z
L.Li
W
ti
w o=> o
z W cc N W
o Q _
¢ O
_ v _
_
p
w
rvoo
�
J
\ONAL FN
O� �G\STE,q
H Q
� z
Lu
a Q�FOF\JP��
IF
HALF SIZE SCALE (12"x18')
1 INCH = 40 FEET
0 20 40
0 20 40
1 INCH = 20 FEET
FULL SIZE SCALE (24"x36')
SHEET NUMBER
PP -2
z
V
O
J
cn
J
O
=
o
m
�
a
�
Q
o
LL
W
Q
z
L.Li
W
_
O
w
rvoo
�
J
W
i
=
Z
><
O
\ONAL FN
O� �G\STE,q
H Q
� z
Lu
a Q�FOF\JP��
IF
HALF SIZE SCALE (12"x18')
1 INCH = 40 FEET
0 20 40
0 20 40
1 INCH = 20 FEET
FULL SIZE SCALE (24"x36')
SHEET NUMBER
PP -2
Fox Hollow Estates Subdivision - Preliminary Plat Narrative
1. The subdivision proposal complies with the applicable provisions of this title. The current project as
proposed meets the applicable provisions of this title.
2. The subdivision proposal complies in principle with all applicable City design standards and
development regulations. All lot sizes, rights-of-way, roadways, utilities etc. have been designed to
comply with the city standards and development regulations.
3. The subdivision proposal complies with all applicable zoning requirements of the underlying zoning
district, applicable overlays, and other applicable development standards. The current project is
anticipated to be located within a Residential (R-2) zone within the city and will follow all the
parameters, guidelines and development standards that the (R-2) zone requires.
4. All public facilities including streets, sidewalks, curbs, gutters, water, sewer, fire protection, and
sanitation services can be provided to the newly created lots and accommodate future extension to
adjacent land. The use of a "control strip" intended to control or prevent the future extension of public
facilities or development of adjacent land is prohibited. The current layout is designed to include all of
the public facilities listed above. Due to the nature of the proposed layout being a dead-end street,
there will be no future extension of the road or utilities beyond what is currently being proposed
within this project.
5. If city public works determines that the proposed subdivision will result in significant traffic impacts
then a "traffic impact study" will be required as part of the commission's review. A significant traffic
impact is generally defined as occurring when:
a. A Proposed development or redevelopment of a site will generate 100 or more new peak hour
trips; or
b. The added volume is equal to 1,000 vehicles per day.
The proposed project will only consist of 12 households. Per the Trip Generation and Distribution
section of the BPTO Traffic Analysis Guidelines, there are 12 trips per single family household per day
(12 x 12 = 144), 1 peak hour AM trip per day (12 x 1 = 12) and 1 peak hour PM trip per day (12 x 1 =
12), the 144 total trips per day and 24 total peak hour trips per day will not generate enough peak
hour trips or total trips to warrant a traffic impact study.
6. The proposal provides for a continuation of a connected transportation system unless topography or
natural features prevents connection to abutting streets or property. As stated in item #4, the proposed
layout is a dead-end street. There will be no future extension of the road or utilities beyond what is
currently being proposed within this project.
7. The proposed subdivision provides for bicycle and pedestrian transportation routes and amenities in
accordance with Bannock Transportation Planning Organization's adopted bicycle and pedestrian plans.
The proposed subdivision will have sidewalks along the frontage of the project that will tie into the
existing sidewalk along Deckyr Drive. This will provide adequate transportation routes for both bicycle
and pedestrian traffic to circulate throughout the neighborhood.
8. Public utilities are provided to the newly created lots in public rights-of-way or in appropriately sized
easements. The proposed project will have new water, irrigationand sewer utilities provided within
the right-of-way as well as a 15' public utility easement provided within the platted subdivision for
public utilities i.e. phone, cable, power and gas, to install their infrastructure to provide services to the
new homes that will be built.
Exhibit 5a:
Comprehensive Plan Future Land Use Map
Fox Hollow Estates Subdivision
Future—Desi 9nation
Commercial
Employment
High Density
Low Density
Medium Density
Mixed Use
CHUBBUCK
290 E. Linden Avenue, Chubbuck, ID 83202
208.237.2430
www.CityofChubbuck.us
Exhibit 5b:
Current Zoning and Requested Change
Fox Hollow Estates Subdivision
L
CHUBBUCK
1DRH0
Zoning
Single Family Residential (R-1)
Limited Residential (R-2)
Limited Residential - P (R -2P)
General Residential (R-3)
Dense Residential (R-4)
Creative Community
M Creative Community -Northside Crossing (CC -NC)
M Creative Community -Harvest Springs (CC -HS)
■ Planned Unit Development (PUD)
M Village (V)
■ Agriculture (A)
® Limited Commercial (C-1)
M General Commercial (C-2)
■ Industrial (I)
M County
F Highway Cooridor (HC)
290 E. Linden Avenue, Chubbuck, ID 83202
208.237.2430
www.CityofChubbuck.us
CHUBBUCK
1AAAA
Exhibit 6:
Evidence of Notice
a. Site Posting
b. Agency notices on file with staff
a. Site Posting
Sign posted April 15, 2026
290 E. Linden Avenue, Chubbuck, ID 83202
208.237.2430
www.CityofChubbuck.us