Loading...
HomeMy WebLinkAboutArbor Court DR Minutes 4.27.21 w applicantOffice of Community Services & Economic Development PO Box 5604 – 5160 Yellowstone Avenue, Chubbuck, ID 83202 208.237.2430 – Fax 208.237.2409 www.CityofChubbuck.us Design Review Minutes (w applicant) Project Name: Arbor Court Apartments  Applicant Name: Daren Crockett  Applicant Address: 244 E. Chubbuck Rd.  Project Address: 295 E. Chubbuck Rd.  Email: dcrockett@vandykmortgage.com  Date: April 27, 2021   Applicant, Daren Crockett, presenting project again before the Committee, with edits. Project originally had 11 units and is now down to 7 with only 2 with backs to Burley Dr. Units against Burley are 10’ from the easement/right of way. Large grass area in the middle to allow for traffic flow and fire and sanitation truck turnaround. There is now a 25’ drive area and 35’ in corners. Each unit has a garage, outside parking spot in front of it and one in front of door. 3 parking stalls per unit plus a few extras within the development Storm water retention in middle grass area Buildings are all interior facing No access from Chubbuck road, existing entry way cut into curb, but will not be used No access to the south, traffic flows internal and back out to Burley 1. Traffic Safety and Traffic Congestion: (ingress, egress, off-street parking, unloading) Distance from Chubbuck to access on Burley, using existing entrance, is approximately 240ft. Requirement for sight triangle on an arterial is 15’ back from curb line, building is 20’ back. Meets requirement. Have engineer look at 35’ internal turn radius for truck turns Applicant will paint ‘no parking’ around island area to prevent congestion Applicant will paint traffic arrows for directional flow – design as one way 2. Traffic Studies, Utility Studies: (as requested) 3. Drainage: (storm & surface water, to be engineered, retained on site) Will need to see design 4. Pretreatment / Nonresidential Waste Water Permit: (grease or oil/silt separator) None 5. Development Agreement (when needed) Yes 6. Structures and Site Layout: (exterior design, buffering, fencing, dumpster enclosure) Exterior design is the same as previously discussed. Will add dormers, pop-outs and different colors, may also do rock fascia on walls. Committee’s biggest concern was the back of buildings facing Burley. Suggestion is to make the backs look similar to the fronts. Applicant only plans for fencing along the west side of the property Recommendation to move dumpster location to the north side of driveway (front loading) 7. Building Department: (professionally approved plans, ADA compliance, dumpster enclosure) Sanitation trucks are front load Dumpster location needs to be moved 10’ off easement/right of way Recommendation to make adjustments with internal design to dumpster location, grassy area and landscaping along Burley Have surveyor finish drawings, show elevations, windows, colors, etc. Architectural amenities will be important especially on backs and sides of units next to Burley, Chubbuck and Kinport. 8. Signs / Advertising: (advertising signs, height, structure) May put monument sign in grassy area, nothing overhead 9. Landscaping: (ordinance copy, approved tree list) 20’ of landscaping on Chubbuck and 20’ on Kinport all grass and trees Requirement of 10’ between sidewalk and building Requirement is 1 tree/shrub every 50 feet (along Burley and Chubbuck) City will provide list of approved trees, small species can be located in the 10’ strip. 10. Exterior lighting: (light shielding, light trespass) Photo cell light on every unit, every other forward facing every other backward facing Ensure no light trespass 11. Development: (platting, addressing) Platting will be required 12. Fire Department: (knox Box, fire hydrant locations, sprinkling, visible street address) One hydrant in island towards the north may be sufficient 13. Police Department: (safety issues) None 14. Business License: (before opening) N/A