Loading...
HomeMy WebLinkAbout003.13.17 Starr Corp Planning Department PO Box 5604 – 5160 Yellowstone Avenue, Chubbuck, ID 83202 208.237.2430 – Fax 208.237.2409 www.CityofChubbuck.us Design Review Meeting March 13, 2017 Applicant: Starr Corporation, Box 46, Twin Falls, ID 83303 Proposed site address: 147 Circle Inn Present: Mayor England; Rodney Burch, Public Works Director; Paul Andrus, City Planner; Bridger Morrison, City Engineer; Ken Quinn, Police Captain; Ray Griffin, Building Official; Merlin Miller, Fire Marshal; Tom Holmes, City Attorney; Nelli Simmons, Office Administrator. Meeting today is a site plan review for changing some of the fencing around the building and adding gates. One gate is manual opening with the second exit gate bring automatic. The manual gate will be open during business hours. Brad Schroder was in attendance from Starr Corporation. Poleline and Alameda is where their office is now. They bought the old Park a Way RV building on Circle Inn. 6’ high chain link fence with privacy slats will surround their yard. Large equipment will be stored in the yard when not on a job site. Front area will also be fenced. PROJECT REQUIREMENTS TRAFFIC SAFETY AND TRAFFIC CONGESTION: no issues TRAFFIC STUDIES, UTILITY STUDIES: not needed OUTDOOR ADVERTISING: Ray will process the sign permit application. South east corner of the lot is where the company sign will go. The store front will be moved to the east side of the building and will have a sign on it. LANDSCAPING: 5% of the paved area needs to be landscaped. A 10’ landscaping strip is required on the street frontage. 1 tree every 50 feet needs to be planted, they can be clumped together. Acceptable tree list was provided. Landscaping strip cannot go away. The grass can be changed to rock. STRUCTURES AND SITE LAYOUT: Landscaping plan where the company sign is on the south east corner will need to be submitted to the City. DRAINAGE: Stormwater drainage will be engineered and retained on site. Now it drains to the wet well by O’Reilly’s. If more paving is done the storm water plan will need to be approved by the City. PRETREATMENT: No additional drains are being added. EXTERIOR LIGHTING: Lighting is required to be shielded to prevent light trespass. ENGINEERING: Platting has been done. FIRE DEPARTMENT: Knox box will be required and a visible street address. Knox box needs to be on the front of the building. BUILDING DEPARTMENT: The electrical inspector needs electrical drawings, no stamp is needed. No plumbing is involved in this project. There is not a separate fencing permit. It will be included in the building permit application and permit. POLICE DEPARTMENT: no issues NONRESIDENTIAL WASTEWATER PERMIT: na BUSINESS LICENSE: A business license application was emailed to Brad. DEVELOPMENT AGREEMENT: na Minutes from today’s meeting were e-mailed to brad@starrcorporation.com on 3.13.17