SECTION 1: Amendment to uni-
form Building Code. Ordinance
No. 148 of the City of Chubbuck,
Idaho, enacted on the 24th day of
February, 1976, adopting the Uni-
form Building Code (with provi-
sions for adopting subsequent edi-
tions of the Cade by resoulution),
is hereby amended by adding
thereto sections 2(A) and 2(B), to
be inserted following the existing
Section 2 of said Ordinance as
fol lows:
"SECTION 2A. Amendments to
Section 2614 (d), 1979 Uniform
Building Code "Design and Rein-
forcement of Walls" and to com-
parable section(s) of subsequent
editions of Code.
(a} Not less than four bars of #4
rebar shall be placed horizontally
in a continuous manner in each
full wall, with all joints lapped a
minimum of 15 inches; provided,
however, (a) that the builder, in
his discretion and with, approval
of the city building official, may
place. not less than two bars of #4
rebar in each such wall and not
less than two bars of #4 rebar in
the footing for the wall, and (b)
that in the case of a half wall, the
builder shall place not less than
two bars of #4 rebar in each such
wall, and rebar in the footing
shall not be required unless
deemed necessary by the city
building official due to said condi-
tions or other factors.
(b) For windows over 4 feet in
width, appropriate design shall be
made to transfer weight of wail
and roof loads over window to
walls.
(c) Three #4 rebar ^hail be placed
in the wall where stairs are to be
poured adjoining the wall. Bars
are to extend a minimum of 2 feet
into the wall and 2 feet into the
step.
(d) It floor and footings are
poured at the same time (Mono-
lithic pour), footing are to be 12
inches deep by 16 incites. wide
tapering at 45 degree angle to-
ward the floor side. Vertical steel
24 inches long must be placed in
footing to anchor wall. #4 bars at
32 inch centers or #5 bars at 48
inch centers are required.
SECTION 2{13}. Amendment to'
Section 1204, 1979 Uniform Build-
ing Code. At the time of construc-
tion,
onstruetion, all finished or unfinished
basements must be provided with
at least one means of emergency
egress in additiion to the main,
door. The additional means of
emergency egress may be by an
additional door, or by a window
not less than 30 inches wide and
being first duly sworn on oath deposes and says: That
was at all times herein mentioned a citizen of the United States of Ameri-
ca, more than 21 years of age, and the Principal Clerk of THE IDAHO
STATE JOURNAL, a daily newspaper, printed and published at Pocatello,
Bannock County, Idaho, and having a general circulation therein.
That the document or notice, a true copy of which is attached, was
published in the said IDAHO STATE JOURNAL, on the following dates,
to -wit:
--- 19CJ
1 19—
, 19-
119
9
,19
, 19--
, 19
That said paper has been continuously and uninterruptedly published
in said County for a period of seventy-eight weeks prior to the publication
of said notice or advertisement and is a newspaper within the meaning
of the laws of Idaho.
Subscribed and sworn to before me this
day of
Notary Public, State of Idaho
Residence: Pocatello, Idaho